Characteristic
This control is mainly applied to food frozen storage proofing box, and its operation is simple and convenient. It adopts France original humidity temperature sensor controller input to obtain high precision humidity temperature control, and can meet the needs of multi-level users with complete & advanced function. This control has humanized design, as long as you set temperature, humidity and time needed, it will start automatic working state and get freezing, refrigeration and proofing automatic control. It has LED luminescent tube coordination indication on panel when it works, can indicate working state of machine with great clarity and simplicity, and is more safe and convenient for users to work.

1、Function characteristics
1)、Using high speed CPU chip design, with rapid movement, accurate control and good stability;
2)、Digitron and indicator light combined display working and alarm state;
3)、Real-time clock setting 0~24 hours;
4)、Setting range of temperature control -18~60℃,control precision:±1℃;
5)、Temperature display range: -50~100℃;
6)、Humidity display setting range 0~99%RH;
7)、Lighting setting 0~9.9 Min;
8)、Defrosting time setting 0~99 Min;
9)、Defrosting delay setting 0~99 Hours;
10)、Defrosting temperature setting 0~99℃;
11)、Compressor delay setting 0~9 Min;
12)、Freezing, refrigeration and proofing automatic control, system year, month and date setting;
13)、Working process power failure memory;
14)、Password setting and data locking avoid operator changing information at will;
15)、Temperature control method:bits model control or proportional control or PID control;
16)、Can select humidity control, temperature control or two control methods combining;
17)、Autostart, scheduling time input;
18)、Multiple password protection setting;
19)、Temperature error shift correction;
20)、Humidity error shift correction;
21)、Upper limit temperature deviation setting;
22)、Upper temperature limit alarm;
23)、Lower temperature limit alarm;
24)、Thermal resistance channels disconnection alarm;
25)、Defrosting temperature channels disconnection or overtemperature alarm;
26)、Humidity channels disconnection alarm.

2、Technical parameter
1)、Temperature, humidity, time and output actions showed respectively on digitron and indicator light.
2)、Output control:( switch output)
        Temperature output one-channel;
        Humidity output one-channel;
        Fan output one-channel;
        Lighting output one-channel;
       Alarm output one-channel;
       Refrigeration output one-channel;
       Defrosting output one-channel;
       Standby relay one-channel.
3)、Input signal: (a set of humidity temperature sensor)
        Temperature signal input one-channel;
        Humidity signal input one-channel;
        Defrosting temperature input one-channel;
        Standby input duplex.
4)、Working power:50~60Hz  AC110V±10% or 50~60Hz AC220V±10%.

1、Cautions in installation
1)、External power supply have abnormal changes will lead to the breakdown of control system, for the safety work of the whole system, please make sure to set safety circuit outside of the control system.
2)、Operator must acquaint himself with the contents of manual before installation, wiring, operation and maintenance. And operator must know very well related mechanical and electronic common sense and all relevant safety cautions.
Notice: Improper operation may cause hazards, including personal injury or equipment accident.
3)、Please install on metal or other flame retardant matters and away from fuel.
4)、Should be safety grounding when use.
5)、Wiring operation must be done by professional electrician.
6)、After the disconnect power is confirmed, operation could be started.

2、Installation environment of system
1)、Should install electricity box of controller in place with good ventilation, oil-proofing and dust proof. If the electric control box is closed, temperature of controller will be too high, affect the normal work and the exhaust fan should be installed; the preference temperature of electricity box is below 50℃ and relative humidity less than 85%RH.
2)、It is necessary to avoid controller being installed too close to AC accessories: contactor, transformer, and so on; the controller must be kept away from strong electromagnetic field environment, for avoiding unnecessary interference and affecting the normal work.
3)、Should not be installed on equipment with greater mechanical shock or trembling.
4)、Please have regular maintenance to ensure controller works without accident.

3、Installation of humidity temperature sensor
The humidity temperature sensor should be inserted into mouse holder with the plane upward, and the probe should be installed on adaptive collection point of air ventilation in the box. In order to collect more effective humidity temperature signal, it is suggested that one small fan blows the probe from the side individually. Probe of humidity temperature sensor should not be in the state of water vapor cover for a long time, because the longevity of probe will be affected. When the work is finished, the fan should continue to blow a period of time and dry out the probe or place the probe in dry environment.

4、Iron plate overall dimension, installation drawing

感兴趣的产品: