SR digital temperature controller

Characteristic
By comparison with traditional XC series moving-coil instrument and common TE series analog instrument, S series digital temperature regulator has the unique advantages of high precision, good shock resistance, clear reading & error-free, long distance inspection and better reliability. The product has multiple adjusting forms of two-position, three-position, time proportioning, controlled silicon continuous adjustment and PID, and can increase transfinite alarm contact output function, is an upgrading product of XC series instrument. It is widely applied to the temperature measurement and automatic control of instrument in the industry of metallurgy, textile, plastic machine, incubator, baking oven, refrigeration chemical industry and medical care within the range of -200~1600℃. And it can display and control the parameter of pressure, flow and fluid level as it equips the corresponding sensor.

Technical parameter
1)、Three-digital digitron displays current actual temperature;
2)、LED light indicates current output state;
3)、Quick and convenient knob indication temperature setting;
4)、Display error: less than ±0.5%±1 word; less than ±1.0%±1 word two-grade;
5)、Setting deviation point: less than ±1.0 word (digital display set value);
6)、Setting point error value: less than ±1% (encode switch setting);
7)、Control point non-sensitive region; less than 0.5%;
8)、Cold-end compensation error: less than 2℃ within 0~40℃;
9)、Time proportion regulating: proportion zone 4%±1% (or appointed) cycle 30±10 Sec (or appointed);
10)、Transfinite alarm: the alarm value appears when the measured signal is more than regulation set value and is about 2%~10% of public variable;
11)、PID regulation:(1)Output 0~10mA;
                                  (2)Load 800±50Ω;
                                  (3)Proportion zone P about 4%;
                                  (4)Integration time I about 4min; 
                                  (5)Differential time D about 30S;
12)、Output pulse signal: phase shift trigger pulse or zero-crossing trigger with amplitude more than 3V, width larger than 40US;
13)、Output contact capacity: AC 220V  3A  or 5A(resistance load);
14)、High power instrument output contact capacity: AC 220V  10A (resistance load);
15)、Output driving solid relay signal: driving current no less than 15mA, no-load voltage not less than 9V, cycle is about 2S;
16)、Temperature coefficient: If deviating 20℃±2℃ when in use in the range of 0~50℃, the temperature coefficient is less than 0.05%/℃;
17)、Working power: 220V±10% 50Hz;
18)、Working conditions: non-corrosive applications with temperature 0~50℃, relative humidity no more than 85%RH.
 

 

1、Installation maintenance
1)、There should be no corrosive gas on site and good connecting point contact.
2)、Should examine the instrument is properly cabled and the temperature-sensing component goes well with instrument index number before power is on.
3)、The mounting location of sensor should reflect the rise and fall of furnace temperature correctly and promptly.
4)、The connection between thermocouple and instrument should use corresponding compensating lead or directly connect to the instrument and the polarity cannot be opposite.
5)、If the instrument displays abnormal, should check whether the thermocouple connection is shorted or turned-off and whether the instrument working voltage is normal.
6)、The environment of instrument storage should meet the technical requirement.
7)、When the instrument is used measuring control of pressure, flow and fluid level, the name, model and specification of equipped component should be informed.
8)、Our company can provide favorable various specifications of sensors, such as thermocouple and resistance.

2、Overall dimension: 96mm×96mm×110mm  

3、Connection diagram