Hotline:400-880-8071
Home Page>Baking equipment controller>MSE-200 dough mixer controller

MSE-200 dough mixer controller

MSE-200 dough mixer controller
Recommended equipment: dough mixer

Characteristic
This controller is mainly applied to the timing mixing control of dough mixer or mixer. It adopts dual-display count-down time setting, with simple and convenient operation. It has LED luminescent tube coordination indication on panel when it works, can indicate working state of machine with great clarity and simplicity. This product is more safe and convenient to work with fan overload protection.

Technical parameter
1)、Using high speed CPU chip design, with rapid movement, accurate control and good stability;
2)、Digitron and indicator light combined display working and alarm state;
3)、Time control range 0~30Min;
4)、Fast/slow hand switching; 
5)、Fast/slow automatic switching;
6)、Rapid relay output;
7)、Slow relay output;
8)、Clockwise relay output;
9)、Reversing relay output;
10)、Working power:50~60Hz   AC220V±10%.
 

1、Cautions in installation
1)、External power supply have abnormal changes will lead to the breakdown of control system, for the safety work of the whole system, please make sure to set safety circuit outside of the control system.
2)、Operator must acquaint himself with the contents of manual before installation, wiring, operation and maintenance. And operator must know very well related mechanical and electronic common sense and all relevant safety cautions.
Notice: Improper operation may cause hazards, including personal injury or equipment accident.
3)、Please install on metal or other flame retardant matters and away from fuel.
4)、Should be safety grounding when use.
5)、Wiring operation must be done by professional electrician.
6)、After the disconnect power is confirmed, operation could be started.

2、System installation and commissioning
1)、Should install electricity box of controller in place with good ventilation, oil-proofing and dust proof. If the electric control box is closed, temperature of controller will be too high, affect the normal work and the exhaust fan should be installed; the preference temperature of electricity box is below 50℃ and relative humidity less than 85%RH.
2)、It is necessary to avoid controller being installed too close to AC accessories, such as contactor, transformer, and so on, for avoiding unnecessary interference.
3)、Please have regular maintenance to ensure controller works without accident.

3、Iron plate overall dimension, installation drawing

感兴趣的产品: