Hotline:400-880-8071
Home Page>Plastic Auxiliary Equipment Controller>MSD-200 drying oven controller

MSD-200 drying oven controller

Recommended equipment: Hopper dryer

Characteristic
MSD-200 drying oven computer controller is the computer control part of box drying oven. This controller adopts high-speed CPU chip design, integrates temperature control and time control, uses PID control temperature, fan and dehumidifying fan automatic control, and has multiple alarm function. As well as it adopts digitron displaying time and temperature, indicating light showing working state and can meet the needs of different users.

1、Function characteristics
1)、Using high speed CPU chip design, with rapid movement, accurate control and good stability;
2)、Digitron and indicator light combined display working and alarm state;
3)、Password setting and data locking avoid operator changing data at will;
4)、Temperature PID control, fan auto-control;
5)、Multiple password protection setting;
6)、Temperature range: 0~400℃;
7)、Range of temperature control: 0~200℃;
8)、Maximum time display of 99 hours 59 Min;
9)、Upper limit temperature deviation alarm;
10)、Absolute value temperature alarm;
11)、Dehumidifying temperature setting;
12)、Deviation temperature setting;
13)、Temperature error shift correction;
14)、Heating thermal inertia setting;
15)、Fan delay setting;
16)、Overtemperature alarm indicating;
17)、Alarm indicating for cut-thermocouples.

2、Technical parameter
1)、Actual temperature,setting temperature, setting time and output actions showed respectively on digitron and indicator light.
2)、Output control:
        Fan output one-route;
        Dehumidifying fan output one-route; 
        Heating output one-route.
3)、Input signal:
        K-type thermocouple input one-route.
4)、Working power:50~60Hz  AC110V±10% or 50~60Hz AC220V±10%.

1、Cautions in installation
1)、External power supply have abnormal changes will lead to the breakdown of control system, for the safety work of the whole system, please make sure to set safety circuit outside of the control system.
2)、Operator must acquaint himself with the contents of manual before installation, wiring, operation and maintenance. And operator must know very well related mechanical and electronic common sense and all relevant safety cautions.
Notice: improper operation may cause hazards, including personal injury or equipment accident.
3)、Please install on metal or other flame retardant matters and away from fuel.
4)、Should be safety grounding when use.
5)、Wiring operation must be done by professional electrician.
6)、After the disconnect power is confirmed, operation could be started.

2、System installation and commissioning
1)、Should install electricity box of controller in place with good ventilation, oil-proofing and dust proof. If the electric control box is closed, temperature of controller will be too high,  affect the normal work and the exhaust fan should be installed; the preference temperature of electricity box is below 50℃ and relative humidity less than 85%RH.
2)、It is necessary to avoid controller being installed too close to AC accessories: contactor, transformer, and so on; the controller must be kept away from strong electromagnetic field environment, for avoiding unnecessary interference and affecting the normal work.
3)、Please have regular maintenance to ensure controller works without accident.

3、Iron plate overall dimension, installation drawing